Auxiliary outputs:
PWM 1 - 4, 9 - 14 and 16 are general purpose switch to
ground 1A current limited outputs. PWM 1 - 4 have
optional free-wheeling diodes for linear control of
variable solenoids. PWM 5,6 and 8 are general purpose
switch to power 1A current limited outputs. All PWM
channels have 33V flyback limiting. PWM 1 is not
available for DBW Cars. PWM 7 and PWM 15 are currently
not available.
NTK
L2H2 Wideband Closed Loop Autotune:
All Nemesis 2.5 ECUs have an L2H21 driver as standard
equipment. There is no need to use an external uego
driver module. The L2H2 , a newer more robust version of
the L1H1 Sensor is a state-of-the-art Nernst Cell sensor
with a rapid response and far more useful rich end output
characteristics than older, non-planar sensors. Heater
current is limited for a controlled warm up, and voltage
limited for constant temperature.
Ignition:
Igniter signals are fully sequential 5V ignition
triggers. Firing mode is positive only (voltage output to
charge coil). Output options are direct fire, wasted
spark and distributor signal.
Support:
Nemesis 2.5 includes many support options that make
seamless plug-and-play possible, and wire in trouble
free. Advanced support features include a dedicated
variable speed fuel pump signal for the WRX, Honda
multiplex bus support (for climate control and gauges),
dedicated circuit opening relay ground signal and
dedicated sensor ground connections that reduce harness
ground wire splicing.
Auxiliary
inputs:
Aux 1, 2 and 3 are 0 - 5V analog or 0 - 12V digital
inputs. In digital mode, the switch point is 2.5V. Aux 3,
4 and 5 are digital only inputs, with a switch point of
2.5V.
Injectors:
The Nemesis 2.5 is capable of running cars up to 8
Cylinders sequentially. Injection modes are sequential,
batch fire and throttle body injection. When not used for
injection, outputs 2 - 8 can be used for staged injection
or general purpose switching, and outputs 2 - 5 can be
used for PWM control .
Sensors:
Analog sensor inputs are coolant temp, air temp, throttle
position, twin knock sensor, twin ego sensor and on-board
3 bar map sensor. Temperature sensors can be configured
for the 2 most common types, and knock sensor inputs can
be amplified.
Digital trigger inputs are vss, trig and sync. These
inputs are magnetic reluctor, Hall effect or optical
sensor compatible.